FixVault

Diagnostic Method

<Monitor 1> 

Judge as abnormal in engine off timer or power supply IC timer when the difference between wake-up request time and power supply IC timer exceeds the threshold value.

When the sub CPU is faulty, wake-up timing is either advancing or retarding compared with normal timing.