FixVault

Air Cleaner Case: Installation

  1. Install the air cleaner case (front).

    Tightening torque: 

    Bolt 

    6 N.m (0.6 kgf-m, 4.4 ft-lb)

    Nut 

    7.5 N.m (0.8 kgf-m, 5.5 ft-lb)

  2. Install the nut to secure the inverter front water pipe to the bracket. (Hybrid model)

    Tightening torque: 

    7.5 N.m (0.8 kgf-m, 5.5 ft-lb)

  3. Install the air cleaner element and the air cleaner case (rear). Ref. to INTAKE (INDUCTION) (H4DO (EXCEPT FOR HEV))>AIR CLEANER ELEMENT>INSTALLATION .
  4. Connect the air intake boot.

    Tightening torque: 

    3 N.m (0.3 kgf-m, 2.2 ft-lb)

  5. Connect the connector to the mass air flow and intake air temperature sensor, and secure the harness with clip.
  6. Install the air intake duct. Ref. to INTAKE (INDUCTION) (H4DO (EXCEPT FOR HEV))>AIR INTAKE DUCT>INSTALLATION .
  7. Connect the ground terminal to battery sensor. Ref. to REPAIR CONTENTS>REPAIR CONTENTS>NOTE>BATTERY .
NOTE: For the hybrid model, connect the battery negative terminal.