FixVault

SRH OFF Switch: Inspection

  1. Measure the resistance between connector terminals.

    Preparation tool: 

    Circuit tester

    G10277284Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Standard
    1 - 4 OFF 1 MΩ or more
    ON Less than 1 Ω
  2. Apply battery voltage between the connector terminals to check lighting condition of illumination inside the switch.
    CAUTION: When applying battery voltage, do not mix up the positive (+) side and the negative (-) side.
    Incorrect polarity connection may cause LED damage inside the switch.
    Terminal No. Inspection conditions Specification
    2 (+) - 3 (-) Apply battery voltage. Light ON
  3. Replace the SRH OFF switch if it is found defective.