Unit Inspection
- Check lock assembly fuel
Check the fuel lock operation when battery voltage is applied between the connector terminals.
Preparation tool:
Circuit tester
Terminal No. Inspection conditions Specification 3 (+) - 1 (-) Connect battery to the terminals OPEN 1 (+) - 3 (-) CLOSE - Replace the lock assembly fuel if faulty is found in the inspection.