Check Intermittent Operation
- Turn the ignition switch to ON.
- Operate the combination switch (wiper) to the INT position.
- Check the stop duration during intermittent operation when intermittent control switch is in FAST and SLOW.
Intermittent stationary time
FAST: Approx. 2 seconds
SLOW: Approx. 16 seconds
- Replace the switch if the inspection result is not within the standard value.