FixVault

VDC Control Module And H/U

  1. Bleed air from the brake line, and perform No. 1) - 22) in section 2. Ref. to BRAKE>AIR BLEEDING>PROCEDURE>BRAKE LINE .
    CAUTION:
    • If there is a possibility that air enters the pressure control section in the VDC control module and H/U, perform steps 11) to 16) in section 2.
    • For normal air bleeding operation, do not operate the sequence control for the VDC control module and H/U. (Operating the sequence control may let air in the normal air bleeding passages move to the pressure control section.)
    • Be sure to perform the ABS sequence control mode first before the VDC sequence control mode.
    NOTE: If there is a possibility that air enters the pressure control section in the VDC control module and H/U, perform the sequence control mode for both of the ABS and VDC systems. (Refer to steps 10) to 16) for brake lining.)