Check Relay
Check the resistance between relay terminals.
Terminal No.
Inspection conditions
Standard
Circuit
1 - 2
Always
1 MΩ or more
Courtesy of SUBARU OF AMERICA, INC.
1 - 2
Apply battery voltage between terminals 4 and 3.
Less than 1 Ω
Replace the relay if the inspection result is not within the standard value.