HVAC System (Diagnostics): Customize: List

Item Initial setting value Setting value Contents
Fresh/Recircle Air Door Auto Mode AUTO AUTO When AUTO mode is actuated, inlet switching is also automatically operated.
MANU Even when AUTO mode is actuated, inlet switching is not automatically operated. (Switching can only be manually operated)
Compressor auto mode AUTO AUTO When AUTO mode is actuated, compressor is also automatically operated.
MANU Even when AUTO mode is actuated, compressor is not automatically operated. (Switching can only be manually operated)
Setting temperature shift 0 -3 Adjust the A/C target value relative to the set temperature.
-2
-1
0
+1
+2
+3
Mode/VentII Yes Yes When AUTO mode is operated, VENT II mode (upper wind: large, lower wind: small) is present.
No When AUTO mode is operated, VENT II mode (upper wind: large, lower wind: small) is absent.
Mode/All Flow Yes Yes When AUTO mode is operated, all-flow mode (wind comes from all blower vents) is present.
No When AUTO mode is operated, all-flow mode (wind comes from all blower vents) is absent.
Mode/HeatIII Yes Yes When AUTO mode is operated, HEAT III mode (footwell/DEF ratio is different) is present.
No When AUTO mode is operated, HEAT III mode (footwell/DEF ratio is different) is absent.
Release Max A/C by Mode Sw Yes Yes When the mode switch is operated in MAX A/C status, MAX A/C status is deactivated.
No Even when the mode switch is operated in MAX A/C status, MAX A/C status is not deactivated.