FixVault

Check Resistance Between Terminals And Perform Unit Inspection

G13225525Courtesy of SUBARU OF AMERICA, INC.
  1. Measure the resistance between "P range" switch connector terminals.
    Terminal No. Inspection conditions Standard
    1 - 2 P range Less than 1 Ω
    Except for P range 1 MΩ or more
  2. Measure the resistance between the shift lock solenoid connector terminals.
    Terminal No. Inspection conditions Standard
    4 - 3 - 27.6 - 30.5 Ω
  3. Check the shift lock solenoid unit.
    Terminal No. Inspection conditions Standard
    3 (+) - 4 (-) Apply battery voltage. The shift lock solenoid operates properly.