FixVault

Camera Initialization

This is a recovery measures prepared for the data failure caused by the low battery voltage during data storage to inside the stereo camera.

CAUTION: Do not usually perform camera initialization because it will clear the camera adjustment and inspection data and/or DTCs.

Perform the procedure only when the camera adjustment and inspection result is NG even if the vehicle parked position is normal as shown in the flowchart described in "A: Procedure". After camera initialization, perform the camera adjustment and inspection in the same procedure as for camera replacement.

  1. Connect the Subaru Select Monitor.
    NOTE: For detailed operation procedures, refer to "Application help".
  2. Turn the ignition switch to ON.
  3. Wait for 10 seconds.
  4. On «Start» display, select «Diagnosis».
  5. On «Vehicle selection» display, enter vehicle information and select «Confirmed».
  6. On «Main Menu» display, select «Each System».
  7. On «Select System» display, select «EyeSight» and then select «Enter».
  8. On «Select Function» display, select «DTC».
  9. Select «Clear Memory» while pressing the pre-collision brake OFF switch and the lane departure warning OFF switch mounted on stereo camera cover assembly at the same time.
  10. Turn the ignition switch to OFF.
  11. Wait for 5 seconds.
  12. Next, perform the clear adjustment value. Ref. to EYESIGHT>CAMERA ADJUSTMENT, INSPECTION>PROCEDURE>ADJUSTMENT VALUE CLEAR .