FixVault

Engine Starting System & Charging System (2.5L): Generator: Removal

  1. Disconnect the ground cable from battery.
  2. Remove the V-belt covers.
    G06344549Courtesy of SUBARU OF AMERICA, INC.
  3. Disconnect the connector and terminal from generator.
    G06345058Courtesy of SUBARU OF AMERICA, INC.
  4. Remove the front side belt. Refer to MECHANICAL(STI)>V-BELT>REMOVAL>FRONT SIDE BELT .
  5. Remove the bolts which install the generator onto bracket.
G10265719Courtesy of SUBARU OF AMERICA, INC.