FixVault

Front Oxygen (A/F) Sensor: Inspection

  1. Check that the front oxygen (A/F) sensor has no deformation, cracks or other damages.
  2. Measure the resistance between front oxygen (A/F) sensor terminals.
    G06344728Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Standard
    1 and 2 2.4±0.24 Ω (when 20°C (68°F))