FixVault

Inspection Of Actuator Unit

  1. CHECK ACTUATOR  .
    1. Disconnect the connector of actuator.
    2. Connect the battery to the actuator connector.

    Connector & terminal 

    RH side: 

    (R170) No. 4 (+) - (R170) No. 1 (-):

    LH side: 

    (R171) No. 4 (+) - (R171) No. 1 (-):

    Does the actuator operate?

    YES  : The actuator is normal.

    NO  : Replace the actuator.