Secondary Speed Sensor: Installation

CAUTION:

If water or oil contacts the connector terminal of secondary speed sensor, replace it with a new part. 

  1. Install the secondary speed sensor using a new O-ring, and connect the connector.
    NOTE:

    Apply CVTF to the O-rings. 

    Tightening torque: 

    5 N.m (0.5 kgf-m, 3.7 ft-lb)

  2. Install the transmission body. Ref. to CONTINUOUSLY VARIABLE TRANSMISSION (TR690)>TRANSMISSION ASSEMBLY>INSTALLATION .