FixVault

VDC OFF Switch: Inspection

  1. Measure the resistance between the VDC OFF switch terminals.
    G10315164Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Standard
    6 - 8 Switch OFF 1 MΩ or more
    Switch ON Less than 1 Ω
  2. Apply battery voltage between the connector terminals to check lighting condition of illumination inside the switch.
    CAUTION:

    When applying battery voltage, do not mix up the positive (+) side and the negative (-) side. 

    Incorrect polarity connection may cause LED damage inside the switch. 

    Terminals No. Inspection conditions Specification
    1 (+) - 4 (-) Apply battery voltage. Light ON
  3. Replace the VDC OFF switch if it is found defective.