FixVault

Check With SUBARU Select Monitor

CAUTION: Before performing the inspection, check the following settings.
  • Wiper deicer setting → "support". If "no support", set to "support" using customize setting.
  • Rear defogger operation mode setting → initial setting or customize setting.
  1. Check the input signal when the rear window defogger switch is operated using Subaru Select Monitor.
    1. Using the Subaru Select Monitor, select [Wiper Deicer Output] from the Data Monitor item list of [Body Control]. Ref. to BODY CONTROL (DIAGNOSTICS)>DATA MONITOR .
    2. Check the displayed data (ON/OFF) by pressing and holding the rear window defogger switch for at least 3 seconds.
  2. Check the operation with rear window defogger switch pressed for at least 3 seconds.
    • When customize setting is "Continuous", it is normal if the operation lasts for 15 minutes or more. However, if the vehicle speed is less than 15 km/h (9 MPH), the operation lasts for 15 minutes and then turns OFF.
    • When customize setting is "Normal", it is normal if the operation lasts for 15 minutes and then turns OFF.
  3. When the operation in  2 above fails, replace the body integrated unit.