FixVault

Electrical Specification

G11257725Courtesy of SUBARU OF AMERICA, INC.
Connector No. Terminal No. Contents Measuring condition Standard
B450 1 Ignition power supply Ignition SW: ON
Measurement between (B450) No. 1 - (B452) No. 1
9 - 16 V
B450 6 (H)_Advanced safety CAN H Digital signal; cannot be measured -
B450 7 (H)_Advanced safety CAN L Digital signal; cannot be measured -
B452 1 Ground Always
Measurement between (B452) No. 1 - (B452) No. 2
10 - 16 V
B452 2 Battery power supply