FixVault

Check Manifold Temperature Sensor Unit

  1. Check the resistance between the terminals at the manifold temperature sensor.
G13198316Courtesy of SUBARU OF AMERICA, INC.
Temperature Terminal No. Standard
-20°C (-4°F) 1 - 2 14.7 - 16.1 kΩ
25°C (77°F) 1.9 - 2.1 kΩ
60°C (140°F) 0.5 - 0.6 kΩ