FixVault

VDC Control Module & H/U

  1. Bleed air from the brake line, and perform No. 1) - 25) in service information 2. Ref. to BRAKE>AIR BLEEDING>PROCEDURE>BRAKE LINE .
CAUTION:
  • If there is a possibility that air enters the pressure control section in the VDC Control Module & H/U, perform steps  12 to  17 in service information 2.
  • For normal air bleeding operation, do not operate the sequence control for the VDC Control Module & H/U. (Operating the sequence control may let air in the normal air bleeding passages move to the pressure control section.)
  • Be sure to perform the ABS sequence control mode first before the VDC sequence control mode.
NOTE: If there is a possibility that air enters the pressure control section in the VDC Control Module & H/U, perform the sequence control mode for both of the ABS and VDC systems. (Refer to steps  11 to  17 for brake lining.)