FixVault

Insulation Resistance

Connect ohmmeter leads to coil positive terminal and coil mounting bracket. Reading on all models should exceed 10 megohms (infinity).

IGNITION COIL RESISTANCE - OHMS

Application Primary Resistance Secondary Resistance
Samurai 1.3-1.6 11,000-14,500