FixVault

Installation Procedure

    Fig 1: View of Manifold Absolute Pressure Sensor Electrical Connector
    GM1348510Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to Fastener Notice in Cautions and Notices.
  1. Install the MAP sensor with the bolt.

    Tighten:  Tighten the MAP sensor bolt to 10 N.m (89 lb in).

  2. Connect the MAP sensor electrical connector.
  3. Connect the negative battery cable.