  1. Disconnect the negative battery cable.
  2. Disconnect the throttle cable by opening the throttle and moving the cable through the release slot.
  3. Fig 1: Disconnecting Throttle Cable
    G01985555Courtesy of SUZUKI OF AMERICA CORP.
  4. Disconnect the vacuum hose from the VIS actuator.
  5. Remove the VIS actuator and the VIS valve.
    NOTE: Make sure the VIS valve flap is closed before removing the VIS valve.
Fig 2: Removing VIS Actuator & VIS Valve
G01985556Courtesy of SUZUKI OF AMERICA CORP.