FixVault

Fuel Pump Relay Inspection

  1. Disconnect negative cable at battery.
  2. Remove fuel pump relay (1), from relay box (2).
  3. Check that there is no continuity between terminal "C" and "B". If there is continuity, replace relay.
  4. Connect battery positive (+) terminal to terminal "B" of relay.

    Connect battery negative (-) terminal "A" of relay.

    Check continuity between terminal "C" and "D".

    If there is no continuity when relay is connected to the battery, replace relay.

    Fig 1: Checking Continuity Between Fuel Pump Relay Terminals
    G04014242Courtesy of SUZUKI OF AMERICA CORP.