FixVault

Secondary Parameters And Enable Conditions

Enable Conditions:



Signal Implausible/Signal Missing:

Enable Conditions:

Crankshaft acquisition active

No Crankshaft error

0 < Engine Speed calculated on last crankshaft tooth period < 416 rpm

Loss of Synchronization:

Flag for crankshaft acquisition synchronized = ON

No Crankshaft error

0 < Engine Speed calculated on last crankshaft tooth period < 416 rpm

Implausible Tooth Period:

Engine running = true

Crankshaft limp-home mode = false

No Crankshaft error

0 < Engine Speed calculated on last crankshaft tooth period < 416 rpm