Secondary Parameters And Enable Conditions

SCP:

Maximum value of anti - bounce counter (12) delay is not reached.

No Failure on all camshaft sensor signals in normal mode

Engine Speed > 512 rpm

Number of ignition sparks = 0

OL/SCG:

Engine Stopped = false

Engine Start = false

Engine Speed > 512 rpm

Cooling Temperature > 20.25 °C

Maximum value of anti - bounce counter delay (24) is not reached.

No Failure on all camshaft sensor signals in normal mode

10.968 V < Battery voltage < 16.0468 V

Number of ignition sparks = 0