FixVault

Secondary Parameters And Enable Conditions

Electrical Error:

Ignition ON

Configuration byte for DIAGCP > 1

Battery voltage condition fulfilled for OBD-II diagnosis = true

Constant signal:

Engine stopped = false

Battery voltage condition fulfilled for OBD-II diagnosis = true

DTP stuck sensor diagnosis inhibition = false

Configuration byte for DIAGCP > 1

Minimum TAM for activation of DIAGCP

> -3.75 °C

Minimum purge flow fluctuation for diagnosis > 0.05 kg/h

Pressure sensor Voltage for Diagnosis > 0.298 V

Minimum vehicle speed for diagnosis > 45 km/h

=> DTP constant signal diagnosis = ON

Noisy Error:

Battery voltage condition fulfilled for OBD-II diagnosis = true

DTP noisy sensor diagnosis inhibition = false

DTP noisy signal diagnosis = active