FixVault

Installation Procedure

Fig 1: Identifying CMP Sensor & Bolt (2 Of 2)
G04841341Courtesy of SUZUKI OF AMERICA CORP.
  1. Install the CMP sensor.
    CAUTION: Refer to FASTENER NOTICE .
  2. Install the CMP sensor bolt.

    Tightening torque 

    Tighten the bolt to 10 N.m (89 lb in)  .

    Fig 2: Connecting Engine Wiring Harness Electrical Connector To Bank 2 Intake CMP Sensor
    G04841342Courtesy of SUZUKI OF AMERICA CORP.
  3. Connect the engine wiring harness electrical connector (8) to the bank 2 intake CMP sensor.
  4. Install the air cleaner assembly. Refer to INSTALLATION PROCEDURE .