FixVault

Removal Procedure

Fig 1: Disconnecting Engine Wiring Harness Electrical Connector From Bank 2 Intake Camshaft Position (CMP) Sensor
G04841339Courtesy of SUZUKI OF AMERICA CORP.
  1. Remove the air cleaner assembly. Refer to REMOVAL PROCEDURE .
  2. Disconnect the engine wiring harness electrical connector (8) from the bank 2 intake camshaft position (CMP) sensor.
    Fig 2: Identifying CMP Sensor & Bolt (1 Of 2)
    G04841340Courtesy of SUZUKI OF AMERICA CORP.
  3. Remove the CMP sensor bolt.
  4. Remove the CMP sensor.