FixVault

Learning Control Initialization

  1. Connect scan tool to DLC (1) with ignition switch OFF.

    Special Tool 

    (A): SUZUKI scan tool 

    Fig 1: Connecting SUZUKI Scan Tool To Data Link Connector
    G04824824Courtesy of SUZUKI OF AMERICA CORP.
  2. Start engine and shift selector lever to "P" range.
  3. Select "Misc Test" mode on scan tool.
  4. Perform "AT learned initialize" on scan tool.