FixVault

CAN Communication Signal Circuit Rationality Monitor

OPERATION

DTCs U0101, U0121, U0155
Monitor execution Not applicable
Monitoring duration 2 sec.
ENABLE CONDITIONS

Parameter Min. Max.
U0101, U0121, U0155 
Battery voltage 10 V -
Engine speed 500 RPM -
TYPICAL MALFUNCTION THRESHOLDS

Time of no message >= 2 sec.