FixVault

CMP Sensor Rationality Monitor

OPERATION

DTC P0340
Monitor execution Not applicable
Monitoring duration 8 revolution
ENABLE CONDITIONS

Parameter Min. Max.
Engine speed - 2000 RPM
CKP sensor No DTC (P0335)
TYPICAL MALFUNCTION THRESHOLDS

Camshaft signal number during 2880° (8 revolution) <= 20
Camshaft signal number during 2880° (8 revolution) >= 28
Camshaft signal number (first BTDC 75 - 5° of 2880° (8 revolution) at engine start) < 20