ENABLED CONDITIONS CHART

Parameter Minimum Maximum
Shift position "D" range
Vehicle speed 10 km/h (6 mile/h) -
Engine speed 450 rpm -
Accelerator pedal position 5% -
Battery voltage 10.5 V -
Transmission range sensor No DTC (P0707, P0705)
CAN communication No DTC (U0100, U0073)