Resistance Testing

Disconnect connector from actuator lead wire. Check actuator resistance. Using an ohmmeter, measure the resistance between terminals listed in table. See Fig 1.

ACTUATOR RESISTANCES

Terminal Nos. Ohms
1-3
All Others 68-71
2-3
Pickup 38
Fig 1: Actuator Connector Terminal Numbers