FixVault

Bi-Metallic Vacuum Switching Valve (BVSV)

  1. Drain coolant from radiator into a suitable container. Remove BVSV from coolant outlet. Cool BVSV to less than 122°F (50°C). Check that air flows from pipe A to pipe C. See Fig 1.
    Fig 1: Testing BVSV Valve Do not submerge valve above threads.
    G43560Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. Heat BVSV to more than 147°F (64°C). Check that air flows from pipe A to pipe B. Apply a liquid sealer to threads of BVSV and reinstall. Fill radiator with coolant. If a problem is found, replace BVSV.