FixVault

Actuator Resistance Testing

Check that actuator resistance is correct. Disconnect connector from actuator lead wire. Using an ohmmeter, measure the resistance between terminals listed in table. See Fig 1

ACTUATOR RESISTANCES

Terminal Nos. Ohms
1-3
All Except Van, Pickup & 4Runner 30
Pickup & 4Runner 71
Van (1) 2
1-2
All Except Van and Pickup 68
Pickup 38
(1) Resistance between terminals 2 and 3 or 1 should change when plate is moved.
Fig 1: Actuator Connector Terminal Numbers
G29887Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002