FixVault

No Load Test

Place starter on bench. Connect a fully-charged 12-volt battery to starter. See Fig 1. Starter should rotate smoothly. Ensure starter draw is less than 50 amps at 11 volts and turns 5000 RPM minimum.

Fig 1: Starter No Load Test