  1. Using vacuum pump, apply 1.18 in. Hg to port "S". See Fig 1. With vacuum applied air should be drawn in at port "Z". Remove vacuum supply.
  2. Apply air pressure at port "Z". Air should escape through air filter. Replace valve assembly if defective.
Fig 1: Checking VCV Operation
G67579Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002