Distributor Advance Specs
DISTRIBUTOR ADVANCE SPECIFICATIONS (4A-F)
| Mechanical Advance RPM |
Degrees BTDC |
| 850 |
Advance Begins |
| 1400 |
5.5 |
| 2800 |
11.5 |
| 3500 |
10.8 |
DISTRIBUTOR ADVANCE SPECIFICATIONS (4A-F)
| Vacuum Advance - In. Hg |
Degrees BTDC |
| Main & Sub |
| 3.5 |
Advance Begins |
| 6.8 |
7.2 |
| 9.5 |
12.0 |
| Sub |
| 7.1 |
Advance Begins |
| 11.8 |
4.0 |