Code 31, 32/Test No. 6 - Airflow Meter Signal
CODE 31,32/TEST NO. 6-AIRFLOW METER SIGNAL TROUBLE
| Terminals | Trouble | Condition | STD Voltage |
|---|---|---|---|
| VC - E2 | No Voltage | Ignition Switch ON | 4 - 6V |
| VS - E2 | " | Ignition Switch ON Measuring Plate CLOSED | 4 - 5V |
| VS - E2 | " | Ignition Switch ON Measuring Plate OPEN | 0.2 - 0.8V |
| VS - E2 | " | Idling | 2 - 4V |
| VS - E2 | " | 3000 RPM | 0.3 - 1.0V |