FixVault

Vacuum Sensor

NOTE: Vacuum sensor may also be referred to as Manifold Absolute Pressure (MAP) sensor. For testing procedures, see SYSTEM/COMPONENT TESTS article in this section.
VACUUM SENSOR SUPPLY VOLTAGE SPECIFICATIONS

Application Voltage
Tercel 4.00-6.00
VACUUM SENSOR OUTPUT VOLTAGE DROP SPECIFICATIONS

Applied Vacuum: In. Hg Voltage Drop
3.94 .3-.5
7.87 .7-.9
11.81 1.1-1.3
15.75 1.5-1.7
19.69 1.9-2.1