Airflow Meter

NOTE: Airflow meter may be referred to as Volume Airflow (VAF) meter or Mass Airflow (MAF) meter.
  1. Turn ignition off. Disconnect electrical connector from airflow meter. Note airflow meter terminal identification. See Fig 1 and Fig 2.
  2. Using ohmmeter, measure resistance between specified terminals. See AIRFLOW METER RESISTANCE SPECIFICATIONS  table. Replace airflow meter if resistance is not within specification.
Fig 1: Identifying Airflow Meter Terminals (2.4L)
G94I45821Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Fig 2: Identifying Airflow Meter Terminals (3.0L)
G94J45822Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
AIRFLOW METER RESISTANCE SPECIFICATIONS

Application & Terminals Ohms
2.4L
E1-FC
Measuring Plate Fully Closed No Continuity
Measuring Plate Other Than Closed 0
E2-VC 100-300
E2-VB 200-400
E2-THA
-4°F (20°C) 10,000-20,000
32°F (0°C) 4000-7000
68°F (20°C) 2000-3000
104°F (40°C) 900-1300
140°F (60°C) 400-700
E2-VS
Measuring Plate Fully Closed 20-400
Measuring Plate Fully Opened 20-1000
3.0L
E1-FC
Measuring Plate Fully Closed No Continuity
Measuring Plate Other Than Closed 0
E2-VC 200-400
E2-THA
-4°F (20°C) 10,000-20,000
32°F (0°C) 4000-7000
68°F (20°C) 2000-3000
104°F (40°C) 900-1300
140°F (60°C) 400-700
E2-VS
Measuring Plate Fully Closed 200-600
Measuring Plate Fully Opened 20-1200