No-Load Test
- Disconnect battery-to-generator terminal "B" wire. Using an ammeter and voltmeter, connect negative ammeter lead t o disconnected generator terminal "B" wire end, and connect positive ammeter lead to generator terminal "B".
- Connect voltmeter positive lead to generator terminal "B" and negative lead to ground. Start engine and increase engine speed to 2000 RPM. Both meters should read within specification. See GENERATOR REGULATED OUTPUT SPECIFICATIONS table.
- If voltage is more than specified, replace IC regulator. If voltage is less than specified, ground "F" (full field) terminal. See Fig 1-Fig 2 . If voltage is more than specified range, replace IC regulator. If voltage is less than specified range, repair or replace generator.
GENERATOR REGULATED OUTPUT SPECIFICATIONS (AT 2000 RPM)
| Temperature | Amps | Volts |
|---|---|---|
| 77°F (25°C) | 10 Or Less | 13.9-15.1 |
| 239°F (115°C) | 10 Or Less | 13.5-14.3 |