FixVault

Oxygen Sensor Heater

Oxygen sensor heater may be used only on various models and oxygen sensor applications. See OXYGEN SENSOR APPLICATION  table.

OXYGEN SENSOR APPLICATION

Application/ Model Main Oxygen Sensor Sub-Oxygen Sensor Sensor Heater
Tercel X X (1)(2) X
(1) Heater used on sub-oxygen sensor.
(2) Heater used on main oxygen sensor.
OXYGEN SENSOR HEATER RESISTANCE SPECIFICATIONS (1)

Application Ohms @ 68°F (20°C)
Tercel 11-16
(1) Measure resistance between sensor terminals +B and HT. For terminal ID, see the illustration in the SYSTEM/COMPONENT TESTS article.