FixVault
Home
›
Toyota
›
1997
›
Supra 3.0 D, Automatic
›
Repair and Diagnosis
›
Engine Performance
›
Engine Controls - Specifications - Non-Turbo
›
Ignition System
›
Ignition Timing
Ignition Timing
IGNITION TIMING (Degrees BTDC @ Idle)
(1)
Application Type
(2)
Base Timing
(3)
ECM Controlled Timing
Supra Non-Turbo
8-12
7-19
(1)
Check with engine at normal operating temperature, transmission in Neutral, parking brake applied, A/C and all accessories off.
(2)
With Jumper Wire (SST 09843-18020) installed between terminals TE1 and E1 on data link connector No. 1.
(3)
With jumper wire removed from data link connector No. 1.