Power Door Lock Control Relay/Integration Relay Circuit Testing: T100

Check for continuity or voltage between ground and specified power door lock control relay/integration relay terminal. See POWER DOOR LOCK CONTROL & INTEGRATION RELAYS CKT SPECS (T100)  table. If relay does not test as specified, repair circuits as necessary.

POWER DOOR LOCK CONTROL & INTEGRATION RELAYS CKT SPECS (T100) (1)

Terminal No. (2) Condition Continuity?
3 Lock Control Switch Or Passenger Door Key Lock/Unlock Switch LOCK Or OFF No
3 Door Lock Control Switch Or Passenger's Door Key Lock & Unlock Switch UNLOCK Yes
4 Door Lock Control Switch Or Door Key Lock & Unlock Switch UNLOCK Or OFF No
4 Door Lock Control Switch Or Door Key Lock & Unlock Switch LOCK Yes
7 Passenger Door Courtesy Switch OFF (Door Closed) No
7 Passenger Door Courtesy Switch ON (Door Opened) Yes
9 Driver Door Lock Switch UNLOCK Yes
9 Driver Door Lock Switch LOCK No
10 Driver Key Lock & Unlock Switch LOCK Or OFF No
10 Driver Key Lock & Unlock Switch UNLOCK Yes
11 Constant Yes
12 Passenger Door Lock Switch UNLOCK Yes
12 Passenger Door Lock Switch LOCK No
14 Driver Door Courtesy Switch OFF (Door Closed) No
14 Driver Door Courtesy Switch ON (Door Opened) Yes
2 Constant B+
8 Ignition Switch LOCK Or ACC No Voltage
8 Ignition Switch ON B+
13 Key Unlock Warning Sw. OFF (Ign. Key Removed) No Voltage
13 Key Unlock Warning Switch ON (Ign. Key Set) B+
(1) See Fig 1.
(2) Connect DVOM between specified terminal and ground.
Fig 1: Power Door Lock Control Relay/Integration Relay Connector Terminals (T100)
G98C12676Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002