Inspection Procedure
- Are there any other codes (besides DTC P3060) being output?
YES: Go to relevant DTC chart .
NO: Go to Next Step
- Check resistance of battery temperature sensor
.
Preparation:
- Remove the battery cover.
- Disconnect the battery temperature sensor connector.
Check:
Using an ohmmeter, measure the resistance between terminals.
OK:
STANDARD RESISTANCETerminals Resistance (at 25 °C (77° F) 1-2 9-11 kΩ 3-4 9-11 kΩ 5-6 9-11 kΩ 7-8 9-11 kΩ 9-10 9-11 kΩ NG: Replace the battery temperature sensor .
OK: Check fitting of battery temperature sensor connector and correct if necessary .