Torque Specification: 1MZ-FE

STARTING & CHARGING SYSTEM TORQUE SPECIFICATION (1MZ-FE)

Part Tightened N.m Kgf.cm In.Lbs
Starter Assy
Starter Assy At Engine 42 429 31Ft.Lbs
Starter Wire At Terminal 30 Of Starter 9.8 100 7Ft.Lbs
Air Cleaner Assy At Body 5 51 44
Starter Commutator End Frame Assy At Starter Brush Holder Assy 1.5 15 13
Starter Housing At Magnet Starter Switch Assy 5.9 60 52
Starter Commutator End Frame Assy, Starter Yoke Assy At Starter Housing 5.9 60 52
Lead Wire Of Starter Yoke At Terminal 30 Of Magnet Starter Switch 5.9 60 52
Generator Assy (100A)
Generator Assy At Engine
M8 21 214 15 Ft.Lbs
M10 52 530 38 Ft.Lbs
Wire Harness Clamp 8.4 85 74
Generator Wire At Generator Assy 9.8 100 7 Ft.Lbs
Generator Rectifier End Frame At Drive End Frame 4.5 46 39
Generator Recrifier Holder At Coil Lead On Generator Rectifier End Frame 2.9 30 26
Voltage Regulator At Generator Rectifier End Frame 2.0 20 18
Generator Brush Holder At Generator Rectifier End Frame 2.0 20 18
Rear End Cover At Generator Rectifier Holder 4.4 45 39
Plate Terminal At Generator Rectifier Holder 3.9 39 35
Terminal Insulator At Generator Rectifier Holder 4.1 42 36
Generator Pulley At Generator Rotor 111 1,125 81 Ft.Lbs
Generator Assy (130A)
Generator Assy At Engine
M8 21 214 15 Ft.Lbs
M10 52 530 38 Ft.Lbs
Wire Harness Clamp 8.4 45 74
Generator Wire At Generator Assy 9.8 100 7 Ft.Lbs
Generator Coil Assy At Drive End Frame 5.8 59 74
Generator Brush Holder At Generator Rectifier End Frame 1.8 18 16
Rear End Cover At Generator Rectifier Holder 4.6 47 41
Generator Pulley At Generator Rotor 111 1,125 81 Ft.Lbs