Inspection Procedure
HINT:
This diagnostic chart is based on the premise that the engine is cranked normally. If the engine is not cranked, proceed to the problem symptoms table on PROBLEM SYMPTOMS TABLE .
Hand-held tester:
- Connect hand-held tester, and check STA signal.
PREPARATION:
- Connect the hand-held tester to the DLC3.
- Turn the ignition switch ON and push the hand-held tester main switch ON.
CHECK:
Read the STA signal on the hand-held tester while the starter operates.
OK:
IGNITION SWITCH POSITIONIgnition Switch Position ON START STA Signal OFF ON - OK: Proceed to next circuit inspection shown on problem symptom table (See PROBLEM SYMPTOMS TABLE ).
- NG: Go to next step.
- Check for open in harness and connector between ECM and starter relay (Marking: ST) (See
PROCEDURE
).
- NG: Repair or replace harness or connector.
- OK: Check and replace ECM (See PROCEDURE ).
OBD II scan tool (excluding hand-held tester):
- Check voltage between terminal STA of ECM connector and body ground.
PREPARATION:
Remove the glove compartment (See COMPONENTS ).
CHECK:
Measure the voltage between terminal STA of the ECM connector and body ground during the engine cranking.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK:
Voltage: 6 V or more
- OK: Proceed to next circuit inspection shown on problem symptom table (See PROBLEM SYMPTOMS TABLE ).
- NG: Go to next step.
- Check for open in harness and connector between ECM and starter relay (Marking: ST) (See
PROCEDURE
).
- NG: Repair or replace harness or connector.
- OK: Check and replace ECM (See PROCEDURE ).