FixVault

Inspection Procedure

HINT:

In case of using the hand-held tester, start the inspection from step  1 and in case of not using the hand-held tester, start from step  2.

  1. Check alternator signal using hand-held tester. 

    PREPARATION: 

    Connect the hand-held tester to DLC 3.

    CHECK: 

    Check that the alternator signal operate in DATA LIST (See PRE-CHECK ).

    1. OK: Proceed to next circuit inspection shown on problem symptoms table (See  PROBLEM SYMPTOMS TABLE  ). 
    2. NG: Go to Next Step 
  2. Check alternator (See ). 
    1. NG: Replace the alternator. 
    2. OK: Go to Next Step 
  3. Check wire harness and connector between alternator and Body ECU (See  HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE  ). 
    1. OK: Repair or replace wire harness or connector. 
    2. OK: Proceed to next circuit inspection shown on problem symptoms table (See  PROBLEM SYMPTOMS TABLE  ).