FixVault

Sliding Roof System: Inspection

  1. INSPECT SLIDING ROOF LIMIT SWITCH 
    1. Inspect the sliding roof limit switch continuity.

      Standard: 

      SLIDING ROOF LIMIT SWITCH POSITION - SPECIFIED CONDITION

      Switch Position Terminal No. Specified Condition
      No.1 Limit Switch OFF (SW Pin Released) 4 - 5 No Continuity
      No.1 Limit Switch ON (SW Pin Pushed) 4 - 5 Continuity
      No.2 Limit Switch OFF (SW Pin Released) 4 - 6 No Continuity
      No.2 Limit Switch ON (SW Pin Pushed) 4 - 6 Continuity
      Fig 1: Identifying Sliding Roof Limit Switch Connector Terminal
      G02922420Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      If the result is not as specified, replace the sliding roof drive motor.

  2. INSPECT SLIDING ROOF DRIVE GEAR SUB-ASSY 
    1. Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, and check that the motor turns clockwise (moves to the close side).
      Fig 2: Inspecting Sliding Roof Drive Gear Sub-Assy (1 Of 2)
      G02922421Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Reverse the polarity, check that the motor turns counterclockwise (moves to the open side).

      If the result is not as specified, replace the motor.

      Fig 3: Inspecting Sliding Roof Drive Gear Sub-Assy (2 Of 2)
      G02922422Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. INSPECT SLIDING ROOF MOTOR CIRCUIT BREAKER 
    1. With the sliding roof in the fully opened position, hold the sliding roof switch in the "OPEN" side and check that there is circuit breaker operating noise within 10 to 60 seconds.
      Fig 4: Inspecting Sliding Roof Motor Circuit Breaker (Switch Open)
      G02922423Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. With the sliding roof in the fully opened position, hold the sliding roof switch in the "CLOSE" side and check that the sliding roof begins to close within 60 seconds.

      If the result is not as specified, replace the motor.

      Fig 5: Inspecting Sliding Roof Motor Circuit Breaker (Switch Close)
      G02922424Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  4. INSPECT RELAY (Making: P/W) 
    1. Remove the power window relay from the instrument panel J/B.
    2. Inspect the power window relay.

      Standard: 

      POWER WINDOW RELAY TERMINALS SPECIFIED CONDITION

      Terminal No. Condition Specified Condition
      1 <=> 2 Constant Continuity
      3 <=> 5 Apply Battery Voltage Between Terminals 1 And 2 Continuity

      If the result is not as specified, replace the relay.

      Fig 6: Inspecting Power Window Relay
      G02922425Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002